All DaVinci products are rigorously tested by outside testing agencies to ensure they comply (or exceed) building code and industry standards and certifications. Certifications relate to product performance features such as impact resistance (Class 4), fire retardance (class A) and the like, so that you have the confidence that our products will perform as we say. Recently, DaVinci Slate and Shake have received the highly-coveted acceptance of the ICC-ES, which is the United States' leader in evaluating building products for compliance to code.

Shingle Dimensions

Widths 9", 8", 7", 6", 4"  Thickness at Butt5/8"
Length22"  Thickness at Top 1/4"

Hip - Ridge - Starter - Valley Shingle

  6" Hip & Ridge
(standard)
12" Starter 12" Valley Shingle
Pieces/Bundle 20.0 20.0 10.0
Lineal Ft / Bundle 8.33* 20.0 4.3*
Pieces / Lineal Ft 2.40* 1 2.30*
*At recommended 10" exposure.

Field Shingles per Roofing Square

Roof Pitch CoursingMax. ExposureBundles/SquareShingles/SquareWeight/Square
4” in 12” or greater Straight 10" 8 200 304lbs
4” in 12” or greater Staggered 9" 9 225 342lbs
Note 1: All calculations are based on using the recommended 3/8" gap between shingles.
Note 2: Felt interlay is suggested on any pitch and required on pitches less than 6" in 12".

Packing and Shipping Information

 

Testing Summary

 # ShinglesWeight  Type of Test Standard Results
Per Bundle 25 38   Fire Test ASTM E-108/UL790 Class A*
Per Pallet** 1,200 1,824 lbs   Impact Test UL 2218 Class 4
Per Truckload*** 28,800 43,776 lbs   Wind Test UL 997 Certified to 110 MPH
*All weights are approximate
**48 Bundles per Pallet
***24 Pallets per Truckload
Miami Dade County, Florida NOA
   No. 06-308.03 Exp. 7/12/12
ICC-ES ESR-2119

 


1413 Osage Ave. Kansas City, KS 66105 | Phone: 913-599-0766 | Fax: 913-599-0065
Toll-free: 800-DaVinci (328-4624)