Specification Chart

Shingle Dimensions
Widths 9" Thickness at Butt 5/8"
Length 22" Thickness at Tip 1/4"
Hip - Ridge - Starter
6" Hip & Ridge
(standard)
One-piece Hip & Ridge 12" Valley Shingle 12" Starter
Pieces / Bundle 20 10 10 20
Lineal Ft / Bundle 8.33* 8.33* 4.3* 20
Pieces / Lineal Ft 2.40* 2.40* 2.3* 1

* At recommended 10" exposure

Field Shingles per Roofing Square
Coursing Roof Pitch Max. Exposure Bundles / Square Shingles / Square Weight / Square
Straight 4:12 or greater 10" 7 154 283lbs
Staggered 4:12 or greater 9" 7.8 171 315lbs

Note 1: All calculations are based on using the recommended 3/8" gap between shingles.
Note 2: Felt interlay is suggested on any pitch and required on pitches less than 6" in 12"

Packing and Shipping Information
  # Shingles Weight
Per Bundle* 22 41lbs
Per Pallet** 990 1,845lbs
Per Truckload*** 23,760 44,280lbs

* All weights are approximate
** 48 bundles per pallet
*** 24 pallets per truckload

Testing Summary
Type of Test Standard Results
Fire Test ASTM E 108 Class A or Class C*
Impact Test UL 2218 Class 4
Wind Test ASTM D 3161 Certified to 110MPH*

* See DaVinci Installation Instructions for details.
Building Code Approvals: ICC-ES ESR-2119, Miami Dade County, FL NOA No. 06-308.03 Exp. 7/12/12 and TDI